Lithium battery solution for power supply guarantee system of communication base stations
I. Background of the Communication Base Station Support System
The communication base station support system is the general term for a series of facilities and technologies to ensure the stable and reliable operation of communication base stations. The following is a relevant introduction:
Ensure the quality of communication services: Guarantee the normal operation of base stations, reduce communication interruptions and signal interference, and enable users to enjoy stable voice and data communication services.
▲ Enhance operation and maintenance efficiency: Real-time monitoring and remote management enable operation and maintenance personnel to promptly grasp the status of base stations, quickly locate and solve problems, and reduce operation and maintenance costs.
▲ Ensuring network security: The security protection subsystem prevents base station equipment from being stolen, damaged or data from being leaked, ensuring the security and reliability of the communication network.
The power supply guarantee system for base stations, with its new energy lithium batteries featuring high energy density, light weight, long cycle life and environmental friendliness, has gradually become the preferred solution for the power supply guarantee system of communication base stations. This solution is designed to meet the application requirements of lithium batteries in communication base station equipment projects, ensuring that lithium batteries provide safe, efficient and customized power supply solutions for their equipment.
II. Analysis of Equipment Demand Characteristics
1. Equipment application characteristics
▲ Equipment type: Real-time communication, monitoring operations, etc. in plain, mountainous, Marine and other environments.
▲ Working environment: Temperature range, from -40℃ to +70℃, high temperature, extremely cold, high humidity environment, etc.
▲ Power demand: Large continuous/peak power, long battery life, and the voltage platform generally adopts high-voltage platforms such as 48V or 60V.
2. Core requirements for lithium batteries
▲ High safety: Meets the explosion-proof, shock-resistant, waterproof and anti-interference requirements of exploration equipment under harsh working conditions.
▲ Long cycle life: ≥2000 times (80% capacity retention rate).
▲ Fast charging: Supports 1 to 2 hours of fast charging, suitable for high-intensity work.
▲ High-power discharge: The battery supports continuous high-current discharge, meeting the high-current requirements of high-power devices and ensuring their continuous and stable operation.
▲ Intelligent management: The BMS (Battery Management System) is equipped with functions such as overcharge protection, overdischarge protection, overcurrent protection, short-circuit protection, temperature protection, and fault diagnosis, making the battery more intelligent.
▲ Discharge temperature range: -40℃ to +70℃. In a low-temperature environment of -40℃, the battery's discharge efficiency is over 70%. A wider range of ambient temperature adaptability.
▲ Charging temperature: -20 ℃ to +50℃ range, with a wider adaptability to environmental temperatures.
III. Scheme Design
1. Battery selection
▲ Cell types: Ternary lithium batteries (ultra-low temperature, high energy density, high safety), lithium iron phosphate batteries (ultra-low temperature, high safety, long life), sodium-ion batteries (high safety, long life, good low-temperature performance). Different system cells are selected and matched according to different application scenarios.
▲ Battery combination configuration structure: Series and parallel schemes are designed based on the required voltage and capacity of the equipment to meet the requirements of different output voltage platforms.
▲ Structural design: IP68 protection grade, shock-resistant structure, explosion-proof enclosure (suitable for extreme environments or flammable and explosive environments).
2. BMS Management System
Core functions:
▲ Real-time monitoring of the voltage, temperature, SOC (State of Charge), and SOH (State of Health) of individual battery cells.
▲ The battery charging active balancing technology enhances the consistency of usage among battery cells and extends the lifespan of the battery pack.
▲ The I2C/SMBUS/CAN/RS485 communication interface enables data interaction and communication with the main control system of the equipment.
The Coulomb computing method makes the battery SOC more accurate and the battery smarter.
3. Charging solution
▲ Charging equipment: Customized smart charger/charger/charging cabinet/solar photovoltaic, supporting constant current and constant voltage (CC-CV) charging.
▲ Charging strategy: Select fast charging or slow charging mode based on the working conditions to prevent battery overload.
▲ Intelligent control and management: Based on the technical performance characteristics of the battery, the battery charging process and fault diagnosis are intelligently controlled.
IV. Safety and Compliance
1. Safety protection
▲ Thermal management: By adopting a reasonable structural layout, thermal runaway is reduced. Air cooling/liquid cooling systems can be used (for high-power scenarios) to ensure temperature uniformity during battery use and effectively control battery thermal runaway.
▲ Fault protection: Multiple hardware protection mechanisms such as overcharge, overdischarge, short circuit, overcurrent, and over-temperature.
▲ Fault protection: Multiple hardware protection mechanisms such as short circuit, overcurrent, and over-temperature.
▲ Explosion-proof certification: The design can pass various safety regulations certifications.
2. Standard compliance
▲ It complies with national standards such as GB31241-2022 (Safety Technical Specification for Lithium-ion Batteries and Battery Packs for Portable Electronic Products), GB 17761-2024 (Safety Technical Specification for Electric Bicycles), GB/T 34131 (Lithium Batteries for Power Storage), GB 38031 (Safety Requirements for Batteries for Electric Vehicles), etc.
▲ How to obtain domestic and international certifications: GB certification, UN38.3 certification, UL certification, IEC certification, CE certification and other various certification requirements;
V. Project Implementation Plan
Number |
Progress stage |
Project content |
Periodic plan |
1 |
Demand research |
Equipment parameter and working condition data collection |
Within one week |
2 |
Scheme design |
Customized battery packs and BMS development |
2~3weeks |
3 |
Sample testing | Charging and discharging, high and low temperature, safety protection, structural performance verification testing, design compliance verification testing |
3~4weeks |
4 |
Small-batch trial production | Material preparation plan, production assembly, aging, and full inspection and testing |
2~3weeks |
5 |
Medium-batch trial production | Material preparation plan, production assembly, aging, and full inspection and testing |
2~3weeks |
6 |
Mass production | Material preparation plan, production assembly, aging, and full inspection and testing |
4~6weeks |
7 |
Delivery, transportation and maintenance | Installation and commissioning, operation training | Within one week |
VI. Economic Benefit Analysis
1.In terms of cost
▲ The initial investment in spare lithium batteries is relatively large, but they have an absolute advantage in terms of long-term usage costs.
2. Energy-saving benefits:
▲ The charging efficiency is over 95%, which can significantly reduce energy consumption compared with AC power supply.
3. Maintenance cost:
▲ Maintenance-free design reduces AC circuit maintenance and personnel costs.
VII. After-sales Service
1. Warranty period: 1 to 5 years of after-sales warranty, with a lifespan of 500 to 2,000 cycles or more (whichever comes first).
2. Remote monitoring: According to the actual demand status, the cloud platform provides real-time monitoring of the battery status and early warning of potential faults.
3. Emergency Response: Respond within 4 hours, provide solutions within 8 hours, and offer on-site technical support within 24 to 48 hours.
Hint:
▲ The plan needs to be refined based on specific equipment parameters (such as voltage, capacity, and size limitations).
▲ If special environments (such as explosion-proof and aerospace) are involved, corresponding protective designs need to be added.
▲ It is recommended to conduct joint debugging with the equipment manufacturer to ensure that the battery is compatible with the entire machine system